Citizen meters
Our meter factory is equipped with computerized automatic Test Bench for calibration and testing of meters. The high voltage testing machine for the insulation test of meters and electronically operated in our factory, with a phase of 200,000 pieces /annum that ensures high performance. Due to the increasing demand for our single phase analogue and electronic meters amongst customers, we have taken the initiative to install test benches with efficiency much as before for increasing the capacity denoted.
(1) Single Phase Prepaid Smart Meter:
The CMLZY94-M/KP meter is a smart prepaid meter in our Country. It has four-quadrant active energy, four-quadrant reactive energy, multiple anti-tamper detection functions, maximum 8-rate TOU design, and strong magnetic field detection. Meter is applicable for AMI communication protocol DLMS/COSEM standard and supports local or remote online software upgrade function.
CMLZY94-M/KP Single Phase Smart Prepaid Meter, LCD monitor with battery backup.
Rating: 230V, 5(60) Ampere, Accuracy Class-1.0, Keypad base prepaid meter, KG integrated (USA) with PLC function.
(2) Three Phase Prepaid Smart Meter:
The CMLZY66-M/KP three phase prepaid smart keyboard is a new generation of Smart Meter with is equipped with STS prepaid function. Remote and credit recharge is available through optional PLC/RF/GPRS communication modules.
CMLZY66-M/KP Three Phase Smart Prepaid Meter, LCD monitor with battery backup. Rating: 3x240V, 5(60) ~ 10(100) Ampere, Accuracy Class-1.0, Keypad base prepaid meter, KG integrated (USA) with PLC function.
Specifications:
Operating temperature range -25°C to +55°C
Extreme operating temperature range -40 ° C to +70 ° C
Shipping and storage temperature -45°C to +85°C
Relative humidity 95%, no frost
Frequency range 50Hz±5%, 60Hz±5%
Power consumption <1.5W, 6VA
Impact voltage 6kV
AC voltage 4kV
Electrical fast transient pulse group 4kV
Clock error 0.5 seconds/day
Power supply switching power supply technology, low voltage start-up
Pulse output Pulse width: (80 ± 5) ms
Default pulse constant 1000imp/ kWh
(3) Single Phase Digital Meter:
a) CT-2007 Single Phase static kwhr Meter, LCD display with battery backup.
Rating: 230V, (10) 60 Ampere, 50Hz, 1600 imp/Kwhr, Class-1
Neutral-Phase Missing (Double Missing) Meter.
b) CT-2007 Single Phase Static kwhr Meter, LCD display with battery backup.
Rating: 230V, 10(60) Amps, 50Hz, 1600 imp/Kwhr. Class-1.
(4) 3 Phase, 4 Wire Digital Meter:
a) WSE43N-11, 3 Phase 4 Wire Single Tariff Meter
Rating: 3×240/415 V, 10(100) Amps, 50 Hz.
b) WSE43N-11, 3 Phase 4 wire double Tariff Meter
Rating: 3×230/400 V, 10(100) Amp, 50 Hz.
Class-1 (1000 imp/Kwh)
Class-2 (1000 imp/ Kvarh)
c) WSE43N-11, 3 Phase 4 wire double tariff LT/CT Meter
Rating: 3×240/415 V, 5(6) Amps, 50 Hz.
Highlight Points
* Two Directions active. energy, security mode programmable, class 1.0 accuracy
* Instantaneous kW, V, A, PF measurable
* Slide or Block type Maximum Demand configurable, MD interval can be programed
* Up to 8 channels Profile available
* LCD display with OBIS code
* Auxiliary power supply
* Tampering-proof functions
* Event logging
* Up to 12 months’ Historical Recordings
Applied Standard
IEC62052-11, IEC62053-22(kWh, Class 1), IEC62053-23 (kvarh, class 2), IEC62056-21(Communication), IEC62053-21, IEC62052_21, IEC62056-61(BIOS), IEC62055-41, IEC62056-46, IEC62056-53, IEC62056-62, IEC62053-21.